FLASH SALE: EVERYTHING HALF PRICE! LIMITED TIME ONLY!
Site-Log LPMB-1 Data Logger - IC-LPMB-1 Sale!

Site-Log LPMB-1 Data Logger – IC-LPMB-1

  • $986.00
  • $100.00

The SITE-LOG LPMB-1 is a 7-channel, battery powered, stand-alone voltage/current DC data logger, with storage up to 4 MB of data in non-volatile flash memory. Input voltage/current signals can be from sensors, transducers, transmitters or any other common

  • 100% Happiness Backed or Your Money Back
  • Free Delivery on 30+ Orders
  • 60-Day Hassle-Free Returns

SKU: ZT75361996502

Category:

The SITE-LOG LPMB-1 is a 7-channel, battery powered, stand-alone voltage/current DC data logger, with storage up to 4 MB of data in non-volatile flash memory. Input voltage/current signals can be from sensors, transducers, transmitters or any other common voltage/current sources.

Its on-board temperature channel provides environment monitoring and temperature compensation. Its aluminum enclosure makes it excellent in the harshest industrial environment. Plug & Play USB port and versatile custom equation simplify communications and engineering unit conversion. 16-bit ADC makes it well suited for science and laboratory applications where precise and accurate measurements are critical. Features: – 16-bit analog-to-digital converter- Temperature Compensation- 4 megabyte memory size- Both USB and serial interfaces with auto baud rate of up to 115200 bps- Programmable input ranges (2 VDC to 20 VDC)- Over 10 years of battery Life- Powerful software for configuration, downloading, plotting, analysis and alarm reporting- Configurable alarm controls/excitation controls- Wide sampling interval selections (20 milliseconds to 12 hours)- Rugged aluminum enclosure- Coated PCB to protect against moisture, corrosion and mildew.

Specifications

Sampling interval and logging capacity: – 1 minute: 3.98 years (1 enabled channel)- 1 minute: 727 days (2 enabled channel)- 1 minute: 181 days (8 enabled channel)- 10 seconds: 242 days (1 enabled channel)- 10 seconds: 121 days (2 enabled channel)- 10 seconds: 30 days (8 enabled channel)- 1 second: 24 days (1 enabled channel)- 1 second: 12 days (2 enabled channel)- 1 second: 3 days (8 enabled channel)- 100 milliseconds: 58 hours (1 enabled channel)- 100 milliseconds: 29 hours (2 enabled channel)- 100 milliseconds: 7.2 hours (8 enabled channel) Inputs: – Input Connection: Pluggable terminal block for seven external channels, excitation controls and alarm outputs – Internal Channel: On-board thermistor temperature (-40 C ~ 70 C, -40 F ~ 158 F)- CH1 ~ CH4 (Voltage): Programmable ranges for each channel: 0 ~ 20 V, 0 ~ 10 V, 0 ~ 5 V, 0 ~ 2 V – CH5 ~ CH7 (Current): Programmable ranges for each channel: 4 ~ 20 mA, 0 ~ 50 mA.- Resolution: 0.0018% – Accuracy (Thermistor): 0.2 C (0 C ~ 70 C, 32 F ~ 158 F)- Accuracy (voltage channel): 0.05% @ 25 C for 20V, 10V, 5V channels; 0.1% @ 25 C for 2V channel- Accuracy (current channel): 0.1% FSR @ 25 C- Input Impedance for voltage channels: Over 1 MOhms- Overvoltage/overcurrent Protection:up to -3VDC ~ +40 VDC for voltage channels/up to 100mA for current channels Alarms: – Channel Alarms: Two editable alarm thresholds- Alarm Output: ALARM1 & A2/E terminal strips can be configured as alarm outputs Alarm-On: MOSFET(N-Channel) switch on Alarm-Off: MOSFET(N-Channel) switch off Max Power: 200mA @ 24VDC Alarm-On Delay: programmable 0 – 10 minutes delay with 1-minute increment.- Alarm Indicator: On-board LED lights in red when in alarm condition. On-board Memory: – Size: 4 Mega bytes (2 MB readings)- Data Retention: Over 20 years Sampling: – Sampling Interval: 20 milliseconds to 12 hours user selectable (external power required if interval is less than 5 seconds)- Logging Mode: Stop recording or FIFO when memory is full- Logging Activation: Programmable instant, start delay or field push button activation. Communications: – Interface: USB (Mini-USB-B) (USB-A-mini USB-B Cable included) AUX(RJ11) for direct TTL level communications- Baud Rate: Auto-detect baud rate from 2400 to 115200 bps on both USB and AUX. Battery: – Power: Built-in 3.6V Lithium Battery.- Battery Life: 10 years based on 1 minute sampling interval. Physical: – Material: Aluminum enclosure.- Dimension: 88 X 64.2 X 24 mm (3.46 X 2.53 X 0.95 inches).- Weight: 200g- Mounting: Probe/wall-mount holes for hanging/mounting. General: – LED Indicator Tri-Color LED (can be disabled for power saving): Normal Sampling: green when sampling. Alarm: red when sampling. Low Battery: amber when sampling.- Excitation Control: A2/E terminal strip can be configured as excitation control output for driving the power of connected devices.- Warm-up delay interval settings: 10 to 240 seconds with 10-second increment.- Operating Environment: -40 ~ +70 C (-40 F ~ 158 F), 0 ~ 95% RH non-condensing.- Clock Accuracy: 1 mintue per month.- Approvals: CE, FCC

Cost:

$25

Free Shipping:

We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.

Delivery Time:

It usually takes [3-5] business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.

Reviews

There are no reviews yet.

Be the first to review “Site-Log LPMB-1 Data Logger – IC-LPMB-1”

Your email address will not be published. Required fields are marked *