The Fluke 1552A "Stik" Thermometer provides accurate temperature measurements from -80 C to 300 C (-112 F to 572 F) with an accuracy of +/- 0.05 C. This model has a wider measurement range, deeper immersion depth and longer sensor depth compared with the 1
The Fluke 1552A “Stik” Thermometer provides accurate temperature measurements from -80 C to 300 C (-112 F to 572 F) with an accuracy of +/- 0.05 C. This model has a wider measurement range, deeper immersion depth and longer sensor depth compared with the 1551A. The Fluke 1552A delivers repeatable temperature measurements accurate to +/- 0.05 C over its full range and can save up to 10,000 time-stamped readings stored to internal memory. It is rated intrinsically safe for working in indoor or outdoor environments where potentially explosive gases may be present. It’s a great choice for environments that aren’t potential explosive as well such as the floor of a processing plant. The battery operated, portable reference thermometer is a great choice for daily checks of working thermometers, custody transfer temperature determination, PET calibration, LIG calibration, and temperature transmitter calibration and verification.
The stainless steel probe and digital readout are fixed together and calibrated as a system. The large backlit LCD display rotates 90 degrees making it easy to read from any angle. And a user-configurable stability/trend indicator lets you know when your temperature is stable enough to record an accurate measurement. A user-settable auto-off function extends typical battery life to up to 300 hours. And the low-battery indicator and stop-measure function prevents erroneous measurements from being made due to a low battery. Plus you can easily and accurately calibrate the 1552A with a simple three-point calibration function.
Features: – Intrinsically-safe, battery operated, portable reference thermometer- Provides accuracy of +/- 0.05 C (+/- 0.09 F) over full range- Features intrinsically-safe operation (ATEX and IECEx compliant)- Measures -80 C to 160 C (-58 F to 320 F)- Includes datalogging features- Provides user-configurable temperature with Trend/Stability indicator- Displays temperature in C or F- Delivers 300-hour battery life- Shows percent battery-life and low-battery indicators- Includes NVLAP-accreditation and NIST-traceable calibration
– Temperature range: -50 C to 300 C (-112 F to 572 F)- Accuracy (1 year): +/- 0.05 C (+/- 0.09 F)- Temperature resolution: Selectable: 0.1, 0.01, 0.001 (default 0.01)- Sample rate: Selectable: 0.5 seconds, 1 second, 2 seconds (default 1 second)- Readout temperature coefficient: Add +/- 10 ppm/ C of full scale temperature from 10 C to 18 C and 28 C to 50 C- Probe temperature coefficient: 0.00385- Nominal probe resistance at 0 C: 100 ohms- Probe hysteresis: +/- 0.01 C- Response time: 4.8 mm diameter probe (3/16 in): 14 seconds/6.35 mm diameter probe (1/4 in): 21 seconds- Operating temperature range readout: -10 C to 50 C (14 F to 122 F)- Storage temperature: -20 C to 60 C (-4 F to 140 F) 0% to 95% RH, non-condensing- Data memory: Up to 10,000 time-stamped readings stored to internal memory- Logging intervals: 2 seconds, 5 seconds, 10 seconds, 30 seconds, or 60 seconds; 2 minutes, 5 minutes, 10 minutes, 30 minutes, or 60 minutes- Display units: C and F- Sensor type: 100 ohms thin-film RTD- Sensor length: less than or equal to 30 mm- Sensor position (from sheath tip): 3 mm (0.1 in)- Minimum immersion depth: 12 cm (4.8 in)- Probe sheath material: Stainless steel
Warranty:
– 1 Year Manufacturer Warranty + Additional 1 Year Instrument Choice Warranty
$25
We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
It usually takes [3-5] business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.