Please note: Probes and accessories to utilise this logger are offered separately.The HOBO UX120-006M Analog Logger is a high-performance, LCD display data logger for building performance monitoring applications.As Onset's highest-accuracy data logger, it
Please note: Probes and accessories to utilise this logger are offered separately.
The HOBO UX120-006M Analog Logger is a high-performance, LCD display data logger for building performance monitoring applications.
As Onset’s highest-accuracy data logger, it provides twice the accuracy of previous models, a deployment-friendly LCD, and flexible support up to four external sensors for measuring temperature, current, CO2, voltage and more.
The logger is ideal for energy audits, building commissioning studies, equipment scheduling, and more.
– Twice the accuracy over previous models with 16-bit resolution
– Flexible support for a wide range of external sensors
– LCD confirms logger operation and displays near real-time measurement data
– Provides minimum, maximum, average and standard deviation logging options
– On-screen alarms notify you when a sensor reading exceeds set thresholds
– Stores 1.9 million measurements for longer deployments between offloads
Environment:
The UX120-006M Data Logger is for use in Indoor environments
What does the UX120-006 M Data Logger measure:
The UX120-006M Data Logger supports the following measurements (sensors sold separately):
Temperature, 4-20mA, AC Current, AC Voltage, Air Velocity, Carbon Dioxide , Compressed Air Flow, DC Current, DC Voltage, Gauge Pressure, Kilowatts (kW), Volatile Organic Compound.
Measurement Range:– 4-20mA (w/CABLE-4-20MA) 0 to 20.1 mA- 0 to 2.5 V (w/CABLE-2.5-STEREO)- 0 to 5 V (w/CABLE-ADAP5)- 0 to 10 V (w/ CABLE-ADAP10)- 0 to 24 V (w/ CABLE-ADAP24)
Accuracy:- 4-20mA +/- 0.001 mA +/- 0.2% of reading (w/CABLE-4-20MA)- +/- 0.1 mV +/- 0.1% of reading (w/CABLE-2.5-STEREO)- +/- 0.2 mV +/- 0.3% of reading (w/CABLE-ADAP5)- +/- 0.4 mV +/- 0.3% of reading (w/ CABLE-ADAP10)- +/- 1.0 mV +/- 0.3% of reading(w/ CABLE-ADAP24)
Resolution:– 0.3 uA 4-20mA (w/CABLE-4-20MA)- 40 uV (w/CABLE-2.5-STEREO)- 80 uV (w/CABLE-ADAP5)- 160 uV (w/ CABLE-ADAP10)- 384 V (w/ CABLE-ADAP24)
Logger:– Operating range logging: -20 to 70 C; 0 to 95% RH (non-condensing);- Launch/readout: 0 to 50 C per USB specification- Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds- Logging modes: Normal, burst, or statistics- Memory modes: Wrap when full or stop when full- Start modes: Immediate, push button, date & time, or next interval- Stop modes: When memory full, push button, or date & time- Restart mode: Push button- Time accuracy: +/- 1 minute per month at 25 C- Battery life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater- Battery type: Two AAA 1.5 V alkaline batteries, user replaceable- Memory: 4 MB (1.9 million measurements, maximum)- Download type: USB 2.0 interface- Full memory download time: approximately 1.5 minutes- LCD: LCD is visible from 0 to 50 C; the LCD may react slowly or go blank in temperatures outside this range- Size: 10.8 x 5.41 x 2.54 cm- Weight: 107.5 g- Environmental rating: IP50
Measurement Range:– 4-20mA (w/CABLE-4-20MA) 0 to 20.1 mA- 0 to 2.5 V (w/CABLE-2.5-STEREO)- 0 to 5 V (w/CABLE-ADAP5)- 0 to 10 V (w/ CABLE-ADAP10)- 0 to 24 V (w/ CABLE-ADAP24)
Accuracy:– 4-20mA +/- 0.001 mA +/- 0.2% of reading (w/CABLE-4-20MA)- +/- 0.1 mV +/- 0.1% of reading (w/CABLE-2.5-STEREO)- +/- 0.2 mV +/- 0.3% of reading (w/CABLE-ADAP5)- +/- 0.4 mV +/- 0.3% of reading (w/ CABLE-ADAP10)- +/- 1.0 mV +/- 0.3% of reading(w/ CABLE-ADAP24)Resolution:– 0.3 uA 4-20mA (w/CABLE-4-20MA)- 40 uV (w/CABLE-2.5-STEREO)- 80 uV (w/CABLE-ADAP5)- 160 uV (w/ CABLE-ADAP10)- 384 V (w/ CABLE-ADAP24)Logger:– Operating range logging: -20 to 70 C; 0 to 95% RH (non-condensing);- Launch/readout: 0 to 50 C per USB specification- Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds- Logging modes: Normal, burst, or statistics- Memory modes: Wrap when full or stop when full- Start modes: Immediate, push button, date & time, or next interval- Stop modes: When memory full, push button, or date & time- Restart mode: Push button- Time accuracy: +/- 1 minute per month at 25 C- Battery life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater- Battery type: Two AAA 1.5 V alkaline batteries, user replaceable- Memory: 4 MB (1.9 million measurements, maximum)- Download type: USB 2.0 interface- Full memory download time: approximately 1.5 minutes- LCD: LCD is visible from 0 to 50 C; the LCD may react slowly or go blank in temperatures outside this range- Size: 10.8 x 5.41 x 2.54 cm- Weight: 107.5 g- Environmental rating: IP50
$25
We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
It usually takes [3-5] business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.
Reviews
There are no reviews yet.