The NanoVIP TWO PLUS is a modern, compact and powerful portable Power Quality analyzer for professional use; it can be used on single-phase, two-phase, three-phase balanced networks, low and medium voltage as well as on chillers and pumping system to monit
The NanoVIP TWO PLUS is a modern, compact and powerful portable Power Quality analyzer for professional use; it can be used on single-phase, two-phase, three-phase balanced networks, low and medium voltage as well as on chillers and pumping system to monitor all performance parameters.
In addition to its electrical channels, it has 4 sensor channels to read whichever type of transducer: 4..20mA, 0..1V or PT to monitor and store data of whichever system. Thanks to the MRH hardware onboard, it can be connected to a QUADRA measuring network as a DGP device. A long lasting battery and the huge logging capability of data (over 1 year) are distinguishing characteristics that make it an absolute reliable and unique professional tool.
Features: – Light, handy, multilingual, with performance and features at the top of its class- LCD graphic display that allows wide flexibility in the (multilingual menu, waveforms, histograms, personalized pages, drawings, diagrams, pictures, etc.)- Compatible with PC Software NanoStudio dedicated through which you can make advanced analysis of the data stored on uSD- 1 voltage measuring channel (1 phase + neutral) up to 600V CAT III, with the possibility to also measure the DC voltage, with the precision of the +/- 0,25% + err.FS- 1 current input with the possibility to also measure the DC current, with the precision of the +/- 0,25% + err.FS- 4 available transducer channels (4..20mA, 0..1V, PT)- 4 preloaded efficiency modes: chiller, pump, supply and sensors- Automatic verification of the correctness of the device connected to the network- Possibility to use flexible current probe up to 3000A or other captors with full scale set by the user- High capacity batteries that allow a range of campaign more than 24 hours even in the absence of mains power; no country limit when connected to the network- 20 alarms (generic, swells, dips and interruptions)- Energy Measurement in 4 time zones (rates) set Measurements: – Display data refresh: 1 sec.- Voltage (TRMS): 1 input channel 4 MOhm, 2 scales- Current (TRMS): 1 input channel 10kOhm- PowerActive, reactive and apparent. Single phase and total- Energy counters: kWh, kvarh, kVAh- Non electrical measures: Yes, up to 4 independent- Harmonics analysis: Up to 50 degrees- EN50160 analysis: from 500mS up- Transitional analysis: Overcurrent, overvoltage and starting currents Characteristics: – Single phase/Double phase networks: yes- Three phase 4 wires, balanced networks: yes- Three phase 3 wires, balanced networks: yes- Three phase 4 wires, unbalanced networks: no- Three phase 3 wires, unbalanced networks: no- Non electrical measures: Yes, up to 4 sensors- Power analysis: V, I, P, Q, S, F, PF, THD(V)%, THD(I)%, cosj, j, peaks, min, max, mid, max. demand, ecc.- Counters: kWh, kVArh, kVAh (used and generated)- Waves shape: V e I- Harmonics: Values and spectrum up to 50 degrees- Sags: Dips, swells and net interruption- Transitory: Overcurrent and overtension- Test EN 50160: yes- Starting currents: yes- Measurements in DC: yes- K factor: Up to 25 degrees- Alarms: Video- Alarms logs: 5 on video- Hourly tarifs: up to 4- Consumption costs: yes- Measurement campaign: Unlimited, up to SD completion- Safety: 600V CAT III- Protection degree: IP30- Display type: LCD dot matrix with backlight- Languages: English- Spanish ? Italian ? German ? French- Communication: USB to PC- Onboard memory: 64kB- External memory: Micro SD (4GB supplied)- Working temperature range: from -10 to +55 C- HUmidity Max: 95%- External power supply: Wall-plug switching, input 100-240VAC +/- 10% 47-63Hz, changeable plug; output 7,5VDC ? 12W- Battery: 4 x AA MiMh 2100mAh- Autonomy: more than 24h (wireless off)- Dimensions: 203 x 116 x 53 mm- Weight: 580g Norms: – CE conformity: 93/68/CEE (B.T. electrical materials); 89/336/CEE e 2004/108/CE (EMC); 2006/95/CE ? 72/23/CEE (LVD ? Low voltages); 2002/95/CE (RoHS ? Dangerous materials restrictions); 2002/96/CE e 2003/108/CE (WEEE/RAEE ? Wasted electrical and electronics materials).- Safety: EN 61010-1- EMC: EN 61326/EN 61326/A1/EN 61326/A2/EN 61326/A3- Temperature: IEC 60068-2-1 (working); IEC 60068-2-2 (storage)- Vibrations: IEC 60068-2-6- Humidity: IEC 60068-2-30 (humidity)- Overload: IEC 60947-1
$25
We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
It usually takes [3-5] business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.
Reviews
There are no reviews yet.